🌏 Blogs / Articles / News / Classifieds / Press Releases / PSA / Podcast / Poetry / Storytelling

 

cleaning (4)

For scaffolding, our company designs two types of shot blasting machine to clean them. One, hanger type shot blasting machine. Another, roller conveyor shot blasting machine. There are advantages for both kinds of blasting machine.

 

Hanger type shot blasting machine is suitable for short scaffolding, and it needs some times to load and unloading the scaffolding from the hanger. It needs to clean one group then unloading it, then clean next group. It can not do blasting continuously.

 

 

Roller shot blasting machine is suitable for all kinds of scaffolding. It is very easy to loading and unloading the scaffolding, no need to stop to work. And it can achieve blasting continuously.

 

Scaffolding Shot blast Cleaning-Machine to Remove Rust 2

 

Generally, the working efficiency of scaffolding roller conveyor blast machine is higher than scaffolding hanger type shot blasting machine. Hope this two type shot blast cleaning machine can meet your needs.

 

If you are interested in our machine, please feel free to contact us.

 

According to its working principle, shot blasting machine can be divided into two types, that is, wheel blasting and air blasting. QINGGONG MACHINERY shot blasting machine manufacturer a variety of shot blasting machines to meet your different needs. According to the industry, different types of shot blasting machines can be chosen from. To learn more, you may see the “Industry” applications. Contact us to get more information about our shot blasting machine products.

 

Sand blasting room is used to do blasting job of those irregular workpieces.With various shapes, parts can't be easily cleaned by blasting turbines, which can consume large amount of power and blasting media. Automatic wheel blasting machines are not able to blast different parts from different angles. However, sand blast room can well solve the above problems. A sandblasting room consists of a blasting body, sandblasting system, abrasive reclaim system, dust collector system, workpiece conveying system, electric control system, and lighting system.

 

 8466669499?profile=original

Read more…

We successfully installed one unit pipes internal pipe blasting and external shot blasting equipment in South Africa in 2009.

 

 

Pipe internal blasting machine is suitable for large diameter circular steel pipe inner wall cleaning. You can clean the inside diameter of; φ600 ~; φ3500mm, a length of 9-13 meters of round steel pipe. The function of the inner surface of the oxide steel and other attachments to remove so that the pipe surface is metallic colors.

 

 

 

Pipe external shot blasting machine adopts two high-power blasting turbines in the layout of the shot blasting machine mutually symmetric, shot blasting mutually complementary, so as to obtain uniform cleaning effect, you can blast cleaning external diameter of; φ600; φ3500mm, a length of 9-13 meters of round steel pipe.

 

 

 

This external and  internal pipe cleaning equipment has been working very well until now, lots of customers went to investigate, which brought us more orders.

 

According to its working principle, shot blasting machines can be divided into two types, that is, wheel blasting and air blasting. QINGGONG MACHINERY supplies a variety of shot blasting machines to meet your different needs. According to the industry, different types of shot blasting machines can be chosen from. To learn more, you may see the “Industry” applications. Contact us to get more information about our shot blasting meaning products.

 

Sand blasting room is used to do blasting job of those irregular workpieces.With various shapes, parts can't be easily cleaned by blasting turbines, which can consume large amount of power and blasting media. Automatic wheel blasting machines are not able to blast different parts from different angles. However, sand blast room can well solve the above problems. A sandblasting room consists of a blasting body, sandblasting system, abrasive reclaim system, dust collector system, workpiece conveying system, electric control system, and lighting system.

 

 8466746896?profile=original

Read more…

Maintenance

 8466713275?profile=original

  1. General Information

 

Regular cleaning including air duct cleaning and ventilation duct cleaning and maintenance can improve the performance of DurkeeSox system and guarantee the good indoor air quality and optimum air dispersion, different air dispersion model and working environment (dust capacity) decide the different period of cleaning and maintenance.

  1. Maintenance Period Description

 

Following is the advised maintenance period of general situation.

 

2.1 DurkeeSox—EJ 100% Eject without Permeation.

 

Made of non-porous fabric, and usually installed in higher space, So system cleaning and maintenance requirement is not an immediate concern. According to the different work environment requirements, general we suggest the cleaning period is three to five years.

 

2.2 DurkeeSox—PE Permeation with Injection

 

Made of less permeable fabric, most of airflow is distributed through orifices; fabric blockage is not our direct concern. Additional, the system is usually installed in higher space, According to different working status, general advised cleaning period is two to three years.

 

2.3 DurkeeSox—PS Permeation with Slots

 

Made of various permeation fabrics, part of air is distributed through fabric, and the system usually installed in lower space, so when it is discovered that fabric is seriously soiled and worked under lower efficiency, or there is obvious dust on the system surface, we need to clean system. According to different working conditions, general advised cleaning period is one to two years. In the cases of extreme dirty, the fabric may happen discolored as the cleaning.

 

2.4 DurkeeSox—PM 100% Permeation

 

Usually applications are in refrigerated, cooling system such as food processing, regular and effective maintenance is particular important. If the systems operating in dirty or soiled or long time without maintenance, it may results permeability failure or less life of system, According to the different working conditions, general advised cleaning period is every 3 months to half year is better. When cleaning, take down every part from suspended device, then turn out the dirty surface and washing.

 

  1. DurkeesoxMaintenance Procedures & Instruction

 

3.1 Remove DurkeeSox fabric ducts.

 

3.1.1 Firstly plan laundering time, making laundering schedule according to the drawing and jobsite situation.

 

3.1.2 After confirm the laundering schedule, arrange workers and tools which use for take off ducts. Checking the location and remove procedures of each DurkeeSox fabric duct according to the drawing, remember to mark as correctly for all the ducts to avoid missing remove or installation mistake.

 

3.1.3 Confirm AHUs turned off and DurkeeSox fabric duct is on the non-work state. Clear away for some sharp objects below or take the proper protection to avoid any potential damage to DurkeeSox fabric air ducts while removing.

 

3.1.4 Check the location of each zipper connection, from the inlet (The join part between metal ducts with DurkeeSox duct) to turn the zipper cover-up sleeve out and unfasten zipper, then retract fabric duct till to the next zipper unfastened to remove this part together, make the proper marks please! When take down to the end part please loosen the fixed snap clip and remove them together with endcap.

 

3.1.5 According to the above procedures, remove and wash ducts step by step as the laundering schedule.

 

  1. 2 Laundering Instruction:

 

3.2.1 Turn the dirty side out, soak in cold water 15 to 30 minutes without any softener;

 

3.2.2 Cold water washing (water temperature should less than 35℃), do not overexert to wrest.

 

3.2.3 Rinse thoroughly, and drip-dry or dry by airing in the shade, do not insolate to avoid any crimple or shrinkage by high temperature.

 

3.2.4 Serious dirty system might needs to clean more than once.

 

3.2.5 The laundering eligible standard is: surface clean without dusts, the accessories of zipper, hanger, etc are in good condition.

 

3.2.6 Big project maybe needs separate one maintenance to several laundering times, once finished one part, please carefully inspect and confirm the quantity according to the drawing, avoid missing laundering and losing!

 

  1. 3 Installation after washing.

 

3.3.1 Indentify all marks or labels of washed ducts according to the drawing.

 

3.3.2 Find out the DurkeeSox fabric ducts which need to install, hang the snap clip of ducts from the first section to the end section one by one, please to avoid any barrier to clamp snap.

 

3.3.3 Connected by zipper for each section as the correct order. To make sure all zippers covered by protection sleeve.

 

3.3.4 Straight the DurkeeSox system after installation and fixed the snap clip to the end part of to avoid fabric duct draw back.

 

3.3.5 Inspect the whole DurkeeSox system is straight and neat without damaged before starting work.

 

Remark:

 

To make laundering schedule do not take influence to owner’s normal working.

 

  1. Please refer to actually situation If any discrepancies between the drawing and actual situation.

 

  1. Please pay attention to ducts labels on the site of each zipper connection.

 

  1. The above methods are applied for the galvanized cable suspension, For the aluminum track suspension model is just slide out & into the end of DurkeeSox system will be ok!

 

  1. We suggest DurkeeSox detergent for exclusive use.

 

  1. For extremely dirty, it would be possible for little color change deepen during the laundering, we suggest to add M-efficiency diffuser or DurkeeSox fabric diffuser

 

  1. DurkeeSox System Storage Method

 

Please properly storage for DurkeeSox system in case of does not use for a long time to ensure the cleanness and extend the lifecycle of DurkeeSox system.

 

4.1 After stop using, Firstly to confirm whether the both inside & outside of DurkeeSox is clean, or launder it if necessary. (Please refer to the above laundering method).

 

4.2 Please remove DurkeeSox system as the procedures above. Please copy the marked drawing and save in the package.

 

4.3 Please pack & seal the removed ducts in time, and affix to instruction mark for the convenience of future installation.

 

4.4 Please count record in time to avoid lost after removed & packed DurkeeSox system.

 

4.5 Please keep DurkeeSox in the dry & ventilation environment. 4.6 Recheck DurkeeSox system before remove & preserve, check whether the surface of DurkeeSox is in good condition.

 

For any further questions, please call to your local distributor or our service line in China. 86-400-8822-068

Read more…

Multifunctional Insulator Cleaning Agent RS-10

Multifunctional Insulator Cleaning Agent (RS-10) is mainly used for eradicating dirt, dust and contaminations on surface of the power equipment, especially clean that which surface was heavily polluted. After cleaning, RS-10 can significantly enhance the adhesion between the RTV coatings and the surface of insulator.

 

The Advantages of Multifunctional Insulator Cleaning Agent RS-10:

Remove the dust, acid, salt and oil completely;

Environmentally friendly, damaged the equipment;

Enhance the adhesion of coating;

Volatilize quickly, no residue.

 

Insulator Cleaner Classification:

High and low voltage electric porcelain (insulator) cleaning agent;

Composite insulator cleaning agent;

High temperature resistant cleaning agent;

Charged water rinse treatment water degreasing additive;

Environmentally friendly transformer oil cleaning agent;

Transformer charged cleaning agent.

 

Application Scope of Multifunctional Insulator Cleaning Agent RS-10:

  1. Power company, Utility, Power Station, Substation, Transmission Line, Overhead Line & Distribution Line, etc.
  2. Composite Insulator, Silicone Rubber Insulator, Glass or Porcelain Disc Insulator, Bushing, Long Rod Insulator, Hollow Porcelain Insulator, etc.
  3. Different kind of pollution environments, such as slat fog, cement dust, fly ash, oil and other industrial pollutants.

 

It is mainly used to clean the surface of insulators in the power industry and surfaces such as porcelain, glass and synthetic materials. Since the product is crystalline, it is more convenient to carry than the liquid cleaning product; the cleaning process does not require water and is more widely used. It can quickly remove dust, oil, moisture, etc. from the porcelain bottle. The cleaned electric porcelain bottle is clean and tidy, which can effectively extend the service life of the electric porcelain bottle and reduce the chance of dirty flash.

 

Contact us get more details about Multifunctional Insulator Cleaning Agent (RS-10), such as TDS, Application Method, OEM etc. also customer required.

 

The Usage of Multifunctional High Voltage Insulator Cleaning Agent:

Scrubbing and brushing method: The cleaning equipment can be scrubbed or brushed with a dry cloth dipped in an electric porcelain bottle cleaning agent. (Note: when it is not charged)

Spraying method: High-pressure spray washing with a charged cleaning machine can quickly remove dust, oil, moisture, carbon powder, metal powder, surface static electricity and other harmful substances on the insulator, and then dry naturally after washing.

Tips: There are two situations that are not suitable for live operation, one is abnormally hot equipment; the other is in a particularly humid environment. Both of them cannot be cleaned with electricity and need to be cleaned by power failure.

 

Precautions:

In order to avoid skin contact with the cleaning solution for a long time, you need to wear rubber gloves.

When cleaning indoors, pay attention to indoor ventilation.

When charging with electricity, personnel should stand at the upwind.

When opening the bottle cap, please do not face the bottle directly to prevent the liquid in the barrel from splashing (long-term exposure, high pressure inside the barrel).

Avoid washing liquid into the eyes. If you are not careful, rinse immediately with clean water. If you still feel unwell, you should go to the hospital for examination.

 

High voltage insulators for sale on cnruisen.com. RFQ today!8466525677?profile=original

Read more…

🔥Christian Music News