voltage (4)

Station Post Insulator

We offer different kinds of Station Post Insulator for Substation, such as Circuit Breaker (CB), Post Insulator, Disconnector, Potential Transformer (PT), Surge Arrester, etc.

 

Contact us get more details about Station Post Insulator, such as TDS, Application Method, OEM etc.

 

We can supply different type of polymer station post insulators, also customer required.

 

The Introduction of Station Post Insulator

The station post insulator is a special insulation control that can play an important role in overhead transmission lines. In the early years, the station post insulators were mostly used for utility poles. Then it slowly developed into a high-voltage high-voltage wire connection tower with one end hanging a lot of suspended insulators. It was used to increase the creepage distance, usually made of silica gel or ceramic, called insulator.Insulators play two fundamental roles in overhead transmission lines: one is supporting the conductors and the other is preventing current from returning to the ground. Insulators should not fail due to flashover breakdown due to changes in environmental and electrical load conditions, which can compromise the use and operational life of the entire line.

 

The Features of station post insulators high voltage

The insulator has high mechanical strength, small dispersion and safe and reliable operation.

The insulator has good mechanical properties at low temperature.

Excellent stain resistance.

High level of earthquake resistance.

Low radio interference.8466525900?profile=original

Read more…

Multifunctional Insulator Cleaning Agent RS-10

Multifunctional Insulator Cleaning Agent (RS-10) is mainly used for eradicating dirt, dust and contaminations on surface of the power equipment, especially clean that which surface was heavily polluted. After cleaning, RS-10 can significantly enhance the adhesion between the RTV coatings and the surface of insulator.

 

The Advantages of Multifunctional Insulator Cleaning Agent RS-10:

Remove the dust, acid, salt and oil completely;

Environmentally friendly, damaged the equipment;

Enhance the adhesion of coating;

Volatilize quickly, no residue.

 

Insulator Cleaner Classification:

High and low voltage electric porcelain (insulator) cleaning agent;

Composite insulator cleaning agent;

High temperature resistant cleaning agent;

Charged water rinse treatment water degreasing additive;

Environmentally friendly transformer oil cleaning agent;

Transformer charged cleaning agent.

 

Application Scope of Multifunctional Insulator Cleaning Agent RS-10:

  1. Power company, Utility, Power Station, Substation, Transmission Line, Overhead Line & Distribution Line, etc.
  2. Composite Insulator, Silicone Rubber Insulator, Glass or Porcelain Disc Insulator, Bushing, Long Rod Insulator, Hollow Porcelain Insulator, etc.
  3. Different kind of pollution environments, such as slat fog, cement dust, fly ash, oil and other industrial pollutants.

 

It is mainly used to clean the surface of insulators in the power industry and surfaces such as porcelain, glass and synthetic materials. Since the product is crystalline, it is more convenient to carry than the liquid cleaning product; the cleaning process does not require water and is more widely used. It can quickly remove dust, oil, moisture, etc. from the porcelain bottle. The cleaned electric porcelain bottle is clean and tidy, which can effectively extend the service life of the electric porcelain bottle and reduce the chance of dirty flash.

 

Contact us get more details about Multifunctional Insulator Cleaning Agent (RS-10), such as TDS, Application Method, OEM etc. also customer required.

 

The Usage of Multifunctional High Voltage Insulator Cleaning Agent:

Scrubbing and brushing method: The cleaning equipment can be scrubbed or brushed with a dry cloth dipped in an electric porcelain bottle cleaning agent. (Note: when it is not charged)

Spraying method: High-pressure spray washing with a charged cleaning machine can quickly remove dust, oil, moisture, carbon powder, metal powder, surface static electricity and other harmful substances on the insulator, and then dry naturally after washing.

Tips: There are two situations that are not suitable for live operation, one is abnormally hot equipment; the other is in a particularly humid environment. Both of them cannot be cleaned with electricity and need to be cleaned by power failure.

 

Precautions:

In order to avoid skin contact with the cleaning solution for a long time, you need to wear rubber gloves.

When cleaning indoors, pay attention to indoor ventilation.

When charging with electricity, personnel should stand at the upwind.

When opening the bottle cap, please do not face the bottle directly to prevent the liquid in the barrel from splashing (long-term exposure, high pressure inside the barrel).

Avoid washing liquid into the eyes. If you are not careful, rinse immediately with clean water. If you still feel unwell, you should go to the hospital for examination.

 

High voltage insulators for sale on cnruisen.com. RFQ today!8466525677?profile=original

Read more…

Insulator & Electric Series

We offer different kinds of Station Post Insulator for Substation, Line Post Insulator, Disc Suspension Insulator, Hollow & Bushing Insulator, Composite Insulators etc.such as Circuit Breaker (CB), Post Insulator, Disconnector, Potential Transformer (PT), Surge Arrester, etc.

 

Contact us get more details about Station Post Insulator, such as TDS, Application Method, OEM etc.

 

We can supply different type of high voltage ceramic insulators, also customer required.

Read more…

High Voltage Insulator Coating Series

High Voltage Insulator Coating (HVIC) is used on excessive voltage insulators to forestall flashover and arcing, particular in severely contaminated environments. Following the following 2 tips, you will get good results: Clean all surfaces of dust, grease and wax & Check temperature and humidity when applying.

 

High Voltage Coating Function

Insulator contamination, from salt spray, industrial pollutants, and even wasteland sand, can lead to costly power interruptions due to arcing and flashover and lead to well-known preservation issues. In order to reduce protection costs & increase reliability, I’d like to use our high-voltage coating to enhance your utility reputation.

 

The high voltage insulators are exposed to harsh environmental prerequisites as excessive temperature and moisture and as properly as serious pollution due to coastal, industrial, agricultural and desert regions. These factors end result in excessive leakage contemporary over the surface of ceramic and glass insulators that may leads to flashover.

 

Room Temperature Vulcanizing (RTV) silicone rubber coating over the floor of porcelain and glass insulators combines their excessive mechanical electricity with superior hydrophobicity conduct of silicone rubber that leads to extremely discount of leakage cutting-edge in areas with excessive pollution.

 

Their special and patented method presents a particularly hydrophobic surface for its whole life. These coating are no longer affected by using UV light, corona discharge, chemical contaminants, salt, excessive temperature or corrosive environments.

 

Why Choose Ruisen?

Fujian Ruisen New Materials Co., Ltd. with years of extensive, deep and successful experience and presence in hundreds huge projects from Asia to America, is the most famous and highly valued provider of High Voltage Insulator Coating in all over the world. Ruisen RTV-II coating is a room temperature vulcanizing (RTV) silicone rubber product, RTV-II coating is widely used in electrical power system (power plant, overhead line, transmission line, substation, switch yard, distribution etc.) to prevent flash over, arcing etc. under humidity, heavy fog weather or wet weather. Especially in heavy pollution areas such as industrial park, desert and coastal regions.

 

Enhancing gird reliability and eliminate pollution flashover under pollution conditions without compromising physical integrity of equipment.8466526886?profile=original8466525285?profile=original

Read more…