To expand your news reach, consider advertising with our media partner, Patch Media, at https://heypapipromotionsmedia.town.news/. Patch is a nationwide news network comprising over 1,000 hyperlocal websites dedicated to community news across the United States. For press release distribution services, please call or visit https://heypapipromotions.com/advertise.
CM-10M Luminance Colorimeter, the best Luminance Colorimeter for optical measurement of FPD. CM-10 and CM-100, via probe measures the luminance of the product directly and reads the value on the LCD screen. CM-10M with standard measurement software that allows you to control the instrument from a computer for continuous and interval measurement, via software to view data and charts.
CM-10M Colorimeter Characteristic
CM-10 Luminance Colorimeter:
Optional handheld controller.
Convenient and flexible device.
Battery powered, widely used in various luminance measurement.
CM-100 Luminance Colorimeter:
Optional desktop controller.
Robust and precise measurement device.
LCD display designed to show measurement values directly.
It can be used in production or R&D, high-speed and high-precision luminance and chromaticity measurement.
High Sensitive Colorimeter
High Transmittance Filter
High Sensitive Photo Diode
Low Noise, High Sensitive Board Design
High Speed & High Accuracy
Iterative Precision:±0.5%(Lv),0.001(x,y)
Accuracy:±3%(Lv),0.003(x,y)
(≤5cd / m 2 , Tack Time 0.5sec)
CM-10M Colorimeter Advantage
Dark(zero) Calibration
Measurement Dark(Zero) automatically
Imperviousness to temperature and humidity
Wide Iuminance Measurement Range
0.01cd/m2~20,000cd/m2
fast measurement during radical change of Luminance through smart auto-gain Algorithm
Flicker Measurement
Accurate Measurement with High Frequency
Provide Flicker and Luminance Measurement
Spectral Characteristic
The filter response curves are based on the CIE1931 standard
Spectral tolerance of filter curve:≤±1%*λ
CM-10M Colorimeter Specification
Model | CM-10M | CM-10 | CM-100 |
Receptor | Silicon photo cell(CIE 1931 XYZ filter) | ||
Measurement area | Ø10mm | Ø10mm | Ø10mm or Ø20mm |
Working Distance | 30±5mm | ||
Acceptance angle | 5th | ||
Expose time | 1msec~5sec | ||
A/D resolution | 16bit | ||
Display Range | 0.0001 to 20,000cd/m2 | ||
Luminance | Measurement range | 0.01 to 20,000cd/m2 | |
Accuracy*¹ | 0.1~5cd/m2 ±3%(5sec) ≥5cd/m2 ±2%(0.5sec) | ||
Repeatability (σ) * ¹ | 0.1~5cd/m2 1%(5sec) ≥5cd/m2 0.5%(0.5sec) | ||
Chromaticity | Accuracy*¹ | 0.1~5cd/m2 ±0.005(5sec,at white) ≥5cd/m2 ±0.003(0.5sec,at white/mono) | |
Repeatability (σ) * ¹ | 0.1~5cd/m2 0.005(5sec) ≥5cd/m2 0.001(0.5sec) | ||
Flicker | FMA | Display Range:0~100%;Accuracy:±1% | |
JEITA | Measurement range:≥10 cd/m2 | ||
Frequency range:0~128HZ | |||
Accuracy:±0.5db | |||
Measurement Speed | 0.1~5cd/m2 | 5sec | |
≥5cd/m2 | 20/sec | ||
Flicker(JEITA or FMA) | 1024/sec | ||
Interface | USB2.0 |
| USB2.0 |
Operating temperature | 5 to50ºC | ||
Input Voltage | USB 5V | USB 5V | AC220V |
*1. Measurement of luminance and chromaticity in the RayClouds conditions (using the standard LCD screen (6500K, 9300K)).
*Specifications and appearance are subject to change without prior notice.
CM-10M Colorimeter Ordering Details
Name | Category | Number |
Probe | Ø10mm 27MM | CM-P-10 CM-P-27 |
Data Cable | 2m 3m 5m 10m | CM-USB-02 CM-USB-03 CM-USB-05 CM-USB-10 |
Power | 5V-3A | CM-PW-05 |
CM Software | V1.0 | CM-V1.0 |
Software Manual | CM Software | CM-SM-V1 |
Key | USB | CM-KEY-19 |
Calibration Certificate | Standard Light Source A LED Light Source Standard LCD at 6500K | CM-CAL-A CM-CAL-LED CM-CAL-LCD |
Probe Mask(Optional) | Black Mask | CM-PM-01 |
Bracket(Optional)
| Probe Bracket (Big) Probe Bracket (Small) | CM-BL-01 CM-BS 02 |
Instrument Bag(Optional)
| L*W*H (290*90*90mm) | CM-PK-041 |
*Note: Please order the appropriate product specifications according to your needs.