Grounding Conductor

Copper-clad copperweld steel grounding material is a new material developed by Ningbo Zhenhai Beisuda Petrochemical Equipment Co.,Ltd. to replace pure copper. Copper clad ground wire has the following advantages:

With high strength

With low price

High corrosion resistance

High electrical conductivity of copper

 

GROUNDING GROUND CONDUCTORS

In recent years, the copper clad steel rod has been widely applied to UHV lines, petrochemicals, nuclear power, high-speed rail, especially key projects. Copper-clad steel: A material in which the surface of a steel core is uniformly coated with copper, including copper-clad steel bars (for vertical grounding only), copper-clad steel flat steel, and copper-clad steel wire (including copper-clad steel round wire and copper-clad steel stranded wire).

 

Zhejiang, it is a professional enterprice, who focus on production and sales of copper clad steel ground rod. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future. 

 8466530085?profile=original8466530068?profile=original8466529498?profile=original8466529886?profile=original

Read more…

Exothermic Welding Products

Exothermic Welding Products

Exothermic welding, also called hot melt welding, fire-clay welding, thermite welding and explosion welding, is a high-heat principle that utilizes the redox reaction between metals, the operation of which is simple, easy to learn, safe and efficient, and it has significant results in the production of high quality permanent welded joints between homogeneous metals and metals of different materials and is now well known to the public, becoming more popular in more and more architectural designs, and widely required to replace the connection method using conventional metal fixtures.

 

Exothermic Welding Supplies require high-quality graphite to form a cavity mold with a certain shape, such as line style (butt), T-joint (three-way), cross-type joint (four-way) and so on. The mold can be used multiple times, effectively saving costs.

 

Exothermic Welding Advantanges:

  1. Good electrical conductivity: the current-carrying capacity of the welded joint surface is almost the same as that of the metal conductor, and the electrical conductivity is strong.

Experiments have shown that the the change rate of DC resistance before and after welding is close to zero, which is incomparable with any traditional connection mode.

  1. Long and durable life: due to the high temperature fusion between the metal conductors during exothermic welding, an integrated permanent joint is formed, which is very strong and difficult to break and damage.
  2. Strong corrosion resistance: the material of the welded point is mainly copper, and the corrosion resistance is almost the same as that of copper.
  3. The operation is convenient and simple with no need for professionals but can be performed only after pepole are simply trained by professionals.
  4. The requirement for operating environment is low, and no external power source or heat source is required for welding.

 

Operation flow of hot-melt welding

  1. First, the mold and the welded conductor joint should be cleaned, and then the welded conductor should be fixed at the center of the mold cavity.
  2. Close the mold and steadily place a metal protective gasket on the bottom of the mold furnace.
  3. Pour in the exothermic welding flux, and evenly spread the starting powder on the surface of the flux and place it in an environmentally friendly starting powder.
  4. Cover the mold, expose a part of the pyrophoric wrap at the mold opening, and then ignite the starting powder with an igniter.
  5. After the hot-melt flux is ignited, a high temperature reaction occurs in the mold.
  6. After the reaction is completed and cooled, the mold is opened and the welded conductor has been permanently connected.

 

Exothermic Welding for Grounding Precautions Flammable and explosive articles shall not be placed within 2 meters of the site during construction operation. Unrelated personnel shall not stay and operators must wear heat insulation gloves and related protective equipment.

 

Zhejiang, it is a professional enterprice, who focus on production and sales of copper clad earth rod. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future.

8466529281?profile=original8466592088?profile=original8466592655?profile=original8466592280?profile=original

Read more…

Copper Bonded Copperweld Ground/Earth Rod

What is the copper-bonded copperweld steel ground rod?

Product Name: Copper coated copperweld steel ground rod

Production process: electroplating / continuous electroforming

Raw materials: Cold draw high quality mild steel

Product type: one pointed, one flat, two threads (requires with a striker, connector, drill)

Thread production process: mainly consists of two processes: turning before electroplating and rolling after electroplating

Tensile strength: 450-600MPA

Copper layer thickness: more than 0.254mm

Super copper thickness: 0.33-1mm

 

Why choose our Copper-bonded steel ground rod?

  1. Factory history 30 years
  2. Export history 10years
  3. Quality control
  4. Technical skill(copper thickness 0.5mm/0.8mm/1mm)
  5. OEM service
  6. Free sample

 

Copper-bonded copperweld steel ground rod advantags:

  1. Higher tensile strength than pure copper ground rod, can be as high as 600MPA and above
  2. Superior corrosion resistance: underground service life of up to 30-50 years
  3. Compared with pure copper ground rod, it has excellent electrical conductivity of copper and saves cost.
  4. Compared with traditional galvanized ground rods, the conductivity is higher and the corrosion resistance is stronger.
  5. The connection to the grounding grid can be made by exothermic welding, integrated and molded, and the grounding resistance is small, making it a permanent maintenance-free grounding device.

Production reference standard: US UL467, national grid production enterprise standard QDW466-2010, etc.

Copper-bonded copperweld steel ground rod application range:

Lightning protection grounding projects in petrochemical plants, oil storage, power plants, substations, communication base stations, airports, network equipment rooms, etc.

Remarks: Copper-bonded copperweld steel copperweld ground rod steel material and copper plating thickness can be customized according to requirements, the company provides OEM service.

 

Copper bonded earth rod specification 

Copper layer 0.254mm

Model No.

Diameter and Length

Unit Weight

Pack

mm

Kg

BSD-GR1312

13 x 1220  (1/2in x 4ft)

1.27

10

BSD-GR1315

13 x 1500  (1/2in x 5ft)

1.56

10

BSD-GR1318

13 x 1800  (1/2in x 6ft)

1.87

10

BSD-GR1324

13 x 2400  (1/2in x 8ft)

2.50

10

BSD-GR1330

13 x 3000  (1/2in x 10ft)

3.13

10

BSD-GR1412

14.2 x 1220  (5/8in x 4ft)

1.53

10

BSD-GR1415

14.2 x 1500  (5/8in x 5ft)

1.91

10

BSD-GR1418

14.2 x 1800  (5/8in x 6ft)

2.31

10

BSD-GR1424

14.2 x 2400  (5/8in x 8ft)

3.05

5

BSD-GR1430

14.2 x 3000  (5/8in x 10ft)

3.83

5

BSD-GR1718

17.2 x 1800  (3/4in x 6ft)

3.37

5

BSD-GR1724

17.2 x 2400  (3/4in x 8ft )

4.55

5

BSD-GR1730

17.2 x 3000  (3/4in x 10ft )

5.58

3

BSD-GR2530

25 x 3000  (1’ x 10ft )

9.8

3

 

  1. Copper layer 0.33-0.5mm

Model No.

Diameter and Length

Unit Weight

Pack

mm

Kg

BSD-GR1312

13 x 1220  (1/2in x 4ft)

1.275

10

BSD-GR1315

13 x 1500  (1/2in x 5ft)

1.565

10

BSD-GR1318

13 x 1800  (1/2in x 6ft)

1.88

10

BSD-GR1324

13 x 2400  (1/2in x 8ft)

2.51

10

BSD-GR1330

13 x 3000  (1/2in x 10ft)

3.14

10

BSD-GR1412

14.2 x 1220  (5/8in x 4ft)

1.54

10

BSD-GR1415

14.2 x 1500  (5/8in x 5ft)

1.92

10

BSD-GR1418

14.2 x 1800  (5/8in x 6ft)

2.33

10

BSD-GR1424

14.2 x 2400  (5/8in x 8ft)

3.07

5

BSD-GR1430

14.2 x 3000  (5/8in x 10ft)

3.87

5

BSD-GR1718

17.2 x 1800  (3/4in x 6ft)

3.39

5

BSD-GR1724

17.2 x 2400  (3/4in x 8ft )

4.57

5

BSD-GR1730

17.2 x 3000  (3/4in x 10ft )

5.60

3

BSD-GR2530

25 x 3000  (1’ x 10ft )

9.85

3

Remark: If you want copper layer more than 0.5mm,please contact us, we off OEM service.

 

Zhejiang, it is a professional copperweld steel company, who focus on production and sales of copper earthing cable. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future.

8466531498?profile=original8466531480?profile=original8466531655?profile=original8466529886?profile=original

Read more…

Chemical Ground Electrode

Chemical Earth Electrode System

Performance characteristics and working principle of Chemical Ground Electrode:

  1. Chemical ground electrode
  2. Existing soil
  3. Special filler
  4. Ions diffuse around
  5. Expand the conductive range of the soil

 

Chemical Grounding electrode (chemical ground rod) is a new type of grounding system suitable for all kinds of places with high grounding requirements and difficult grounding engineering.

 

The earth electrode system consists of advanced alloy compounds, with a copper tube on the outside to ensure maximum conductivity and long service life. The filling material inside the conductor contains special ionic compounds, which can absorb moisture in the air adequately. Active ions can be effectively released into the soil through the deliquescence, and interact with the moisture in the soil and air to further promote the external slow release and drag reduction of conductors, and to maintain the long-term stability of the resistance value. Compounds in conductors are gradually combined in colloidal transparency over time.

 

By utilizing the conductivity of the colloidal compound, the entire system can be ion-exchanged for a long time, thus forming an ideal electrolytic ion grounding system. After the slow-release filler in the conductor is embedded, the grounding resistance will gradually decrease, reaching a stable value within six months to one year, and the embedded slow-release process can last for several years. The main connecting parts of the ion grounding electrode are hot-melt welded, which has overcome other connection methods and easy connection loosening.

 

The connecting wire is a copper clad steel copperweld stranded wire with a section of 95 mm2 and a length of 3 m and is crimped to the grounding terminal/copper lug to facilitate connection with the grounding grid.

 

Chemical Ground Electrode Specification and models

Products

Models No.

Diameter

mm

Length

mm

Weight

Kg

Impuls run

PH Value

(ΔR)

100Ω·M

Chemical ground Electrode

BSD-CGES55

55

1500

10

≤1%

7+/-5%

0.6

3000

20

≤1%

7+/-5%

0.4

 

The grounding electrode of BEISUDA COMPANY electrolytic ion fully meets the requirements of grounding protection equipment such as UL, NEC, ANS, lEC, BC and other international standards.

 

Chemical Ground Electrode application range

Lightning protection and grounding works for petrochemicals, oil storage, power plants, substations, communication base stations, airports and network computer rooms, etc.

 

Zhejiang, it is a professional enterprice, who focus on production and sales of copper earthing cable. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future. 

 8466530671?profile=original8466530068?profile=original

Read more…

CCS-Stranded Cable

Brief Instruction of Copper Clad Steel Stranded Wire

The copper-clad strand wire is shaped like a cable, which is made of a plurality of copper-clad single wires. Because of its multi-stranded properties, the electrical conductivity and tensile strength are relatively good, and the product can be customized to enhance the elongation rate by multiple heat treatment in the production process, which has increased the strength and toughness of the steel compared with the pure copper strand. Moreover, the good electrical conductivity and corrosion resistance of the copper material are maintained due to the principle of the skin effect. Therefore, it is very popular in many fields of lightning protection and grounding, especially in power plants, substations, high-speed rail, subways, electrified railways, large-scale chemical plants, mechanical plants, communication base stations, transportation, computer rooms, highways and military bases.

 

Copper Clad Steel Cable Characteristics

1.High conductivity (up to 70% and above)

The copper-clad strand wire produced by our company generally has a conductivity of 30%-70%, and more than 70% can be customized according to customer requirements.

 

2.High tensile strength

The multi-stranded copper-clad strand wire has high tensile strength and can be made into copper-clad steel strand wire with high electrical conductivity and high tensile strength after being enhanced by special treatment process to be suitable for special use occasions.

CCS-Stranded Cable

Cable Welding Capsule New

3.Long life

The copper plating of single-stranded copper-clad round steel (cable copperweld) of multi-stranded copper-clad strand is thick, the excellent production process makes copper layer tightly combined and bent 180-360 degrees without cracking and its life is long and can be more than 30 years.

4.Low cost

The characteristics of high conductivity and corrosion resistance have greatly reduced the number of grounding conductors used in grounding projects, which can significantly save costs and achieve outstanding economic benefits.

5.Convenient construction and transportation

The single length of the copper-clad copperweld strand can be up to 100 meters, because the 100-meter package or the hundred-meter cable can be transported more easily. The welding between the grounding grids during the construction is recommended to use the exothermic welding series products produced by our company. There are different shapes of molds for exothermic welding, so that different permanent joints can be randomly welded. The construction operation is simple and easy to learn, and the various conductors of the grounding grid are welded together to become a true maintenance-free device.

Specification and modles:

Model No.

Size

Strands*sigle path

Diameter

Conductivity

mm2

mm

%

BSD-10C

10

7*1.4

4.2

18%---70%

BSD-16C

16

7*1.7

5.1

18%---70%

BSD-25C

25

7*2.14

6.42

18%---70%

BSD-35C

35

7*2.52

7356

 

BSD-50C

50

7*3.00

9

18%---70%

BSD-70C

70

19*1.44

10.7

18%---70%

BSD-95C

95

19*2.52

12.6

18%---70%

BSD-120C

120

19*2.80

14

18%---70%

BSD-150C

150

19*3.15

15.75

18%---70%

BSD-185C

185

37*2.52

17.64

18%---70%

BSD-240C

240

37*2.85

19.95

18%---70%

BSD-300C

300

37*3.15

21.7

18%---70%

 

Note: tinned copper-clad strands and PVC insulated copper-clad strands can be customized according to customer requirements.

 

Zhejiang, it is a professional enterprice, who focus on production and sales of copper clad steel ground rod. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future. 

 8466590663?profile=original8466535696?profile=original8466529498?profile=original8466535679?profile=original

Read more…

CCS Round Wire

0.8 Series  Copper Coated Stainless Steel Wire

Origin of new material development

0.8mm series copper-clad round wire is a new type of material developed by our Company to replace pure copper. Because it has the advantages of high strength, low price, high corrosion resistance and high conductivity of copper, and meanwhile its comprehensive performance is high and its cost is more economical than pure copper grounding device, it has been widely used in UHV lines, petrochemical industry, nuclear power and high-speed railway, especially in key projects in recent years.

 

Copper-clad steel:

The material in which the surface of a steel core is uniformly coated with copper includes copper-clad steel bars (for vertical grounding electrode only), copper-clad steel tape, and copper-clad steel wires (including round wires and stranded wires). According to the production process, it can be divided into continuous casting copper-clad steel and electroplating copper-clad steel.

 

Development of copper-clad steel grounding device

With the increasing voltage level of power lines and the increasing capacity of the system, higher requirements are put forward for the safety and reliability of grounding devices.

 

The traditional method in foreign countries is to use pure copper as the grounding material, but pure copper is expensive and it is a strategic resource, which is not suitable for being massively used as grounding devices in China. From 1910 to 1955, National Bureau of Standards (NBS) conducted corrosion resistance studies of grounding bodies. 36,500 samples collected at 128 test sites throughout the United States represented 333 metal materials consisting of iron, non-ferrous metals and protective coatings, respectively. The test results show that only steel bars and stainless steel bars with copper plating thickness over 0.5mm can be accepted.

 

In addition, continue the statistical data of 8 to 30 years and take the test results of 43 copper samples in different soils, 41 of which were calculated, to get the 0.17mm average pitting depth of 30 years. Therefore, some international standards have determined the thickness of copper coating of copper-clad steel material to be at least 0.25 mm. Considering the hard friction during construction, it is suggested that the thickness of copper coating be defined as 0.5-0.8 mm.

 

In China, copper clad(copperweld) steel materials are widely used in substation grounding grids in areas with high soil resistivity. Because of the characteristics of UHV project, such as high voltage level, large capacity and short power cut window period, combined with the corrosion intensity of groundwater in the area, copper-clad steel grounding devices have been applied in UHV lines and many UHV lines in China use copper-clad steel materials as grounding bodies.

 

Comparison between copper-clad steel grounding and traditional hot-dip galvanized steel grounding device

  1. Corrosion rate comparision
    Annual corrosion rate of grounding materials in some place of Beijing and Tianjin

Material

Beijing Liangxiang

Tianjing Dongli

Stainless stell

0.002

0.003

Pure coper

0.001

0.001

Copper-warm star

0.001

0.001

Galvanized steel

0.176

0.2

 

The test results show that galvanized steel has the most serious corrosion and its corrosion rate is more than 50 times higher than that of pure copper; the corrosion degree of stainless steel is much lower than that of pure copper and copper-clad steel, showing good corrosion resistance; as a copper-steel composite material, the self-corrosion potential of copper-clad steel in soil is basically the same as that of pure copper, and its corrosion rate is the same as that of pure copper; the corrosion rate of the electroplated copper-clad steel with thinner coating is higher than that of the continuous casting copper-clad steel with thicker coating.

 

  1. Analysis and comparison of physical performance in short circuit

If the conductivity of copper were 100% and the conductivity of standard 1020 steel were only 10.8%, the conductivity of copper would be about 10 times that of steel. However, the conductivity of the 30% conductivity copper-clad round wire would be 30%, and the conductivity of the 40% conductivity copper-clad round wire would be 40%, which would be far better than the steel grounding body. Especially under skin effect, the conductivity of copper-plated strands at high frequencies would be much better than that of steel, that is, the conductivity of copper grounding body would be better than that of steel grounding body. The melting point of copper is 1083℃ and the maximum allowable temperature during short circuit is 450℃ ; the melting point of steel is 1510℃ and the maximum allowable temperature during short circuit is 400℃. Therefore, when the grounding body has the same cross section, the copper-clad steel grounding material has better thermal stability.

 

  1. Economic comparison

According to Appendix D of Technical Conditions for Copper-clad Steel for Grounding in Electrical Engineering, the corrosion rates of copper clad steel in different soils are calculated according to the reference values in table. Corrosion rate of pure copper under different soil corrosion grades (mm/a)

 

 

Soil corrosion grade

La extremely weak corrosion

Lb Weak corrosion

II Strong corrosion

III Extremely strong corrosion

Corrosion rate

0.0004-0.001

0.001-0.004

0.004-0.007

0.007-0.021

 

The 0.8mm copper plating thickness is enough to meet the requirement of 60 years of service under the grade of III extremely strong corrosion.

The corrosion rate of galvanized steel is nearly 50 times that of copper-clad steel under the same soil conditions, and the grounding body should be overhauled after being used for 3-5 years.

 

The State Grid has accounted the UHV tower according to the drawings: after the investigation of the market price of material during the construction, the market price of the copper-clad-steel grounding body is calculated at RMB 20 /m, the market price of φ12 galvanized-steel round steel grounding body is calculated at RMB 6 /m and the grounding body laying is calculated according to the grounding construction drawing. During the 30-year whole life cycle, galvanized steel is overhauled every 5 years, of which the cost of material is RMB 20 /m for copper-clad steel and RMB 36/m for galvanized steel, that is, only material cost can be reduced by 80%. Galvanized steel can be overhauled and replaced six times. If the construction cost is RMB 70 /m3 for earthwork and stone works and each base tower is calculated by 23 m3 for excavation, RMB 9660 per base tower will be saved.

 

Copper-clad steel construction

The horizontal laying of the copper-clad steel grounding device is the same as that of the ordinary galvanized round steel, where only the connection method is changed to hot-melt welding, which has reduced the contact resistance between the joints and is more conducive to the release of lightning current.

 

Exothermic welding, also known as "aluminum heat welding", is a simple, high-efficiency, high-quality metal joining process that has been mass-produced and used in China in recent years. Exothermic welding uses chemical reaction heat of metal compounds as heat source and through superheated (reduced) molten metal or indirect heating, a certain shape and size of the melted joint is formed in the cavity of the special graphite mould, which meets the engineering requirements, and finally through cooling and condensation, the welding process is realized. At present, exothermic welding has generally replaced the mechanical connection between metals in the past.

 

Advantages of copper-clad steel

1.It has strong corrosion resistance and will not be disjointed, warped or cracked. The corrosion in the grounding body of the grounding grid is reduced, which has improved the overall operational safety of the equipment;

  1. It has good electrical conductivity and stable electrical performance;
  2. The copper layer and the steel bar achieve molecular bonding, and the grounding bar will not break down when it penetrates into the soil.
  3. The copper-clad-steel grounding material used has high efficiency of reducing the resistance, and the length of the horizontal grounding body is reduced by 1/3 for the design of the high-resistance section, greatly reducing the excavation amount of the earthwork;
  4. The design and use of exothermic welding technology is very suitable for the needs of field construction, greatly improving work efficiency and effectively shortening the construction period.

 

Performance parameters of copper-clad steel wire

Copper layer thickness:0.8mm; tensile strength: greater than 500MPa; copper-clad steel bent 180° without peeling off copper layer.

Specification of 0.8mm series copper-clad round steel: Soft copper-clad round bars are generally packaged in hanks or rolls, 100 meters per roll, easy to transport, suitable for laying of large grounding grids and horizontal grounding lines.

Usage:key projects, large grounding grids and horizontal grounding wires in industries with higher lightning protection requirements, etc.

 

Model No.

Dimensions (mm)

Copper Layer(mm)

BSD-GW-R10S

10

0.8/0.5/0.25

BSD-GW-R12S

12

0.8/0.5/0.25

BSD-GW-R14S

14

0.8/0.5/0.25

 

Note:

  1. If the thickness of copper layer is required to be 1 mm, please contact us directly.
  2. We undertake custom-made zinc-clad steel ground rod and round steel.

 

Production method of copper clad steel technical field The invention specifically relates to a production method of copper clad steel.

 

Background technologycopper clad steel

The conductivity of existing copper clad steel products is not good, far inferior to that of pure copper products. The reason is that the overall product performance is insufficient when copper is coated on steel materials in the process.

 

Summary of the invention

In view of the above technical problems, the invention provides a production method of copper clad steel.

A copper clad steel production method comprises the following steps:

  1. Surface treatment of steel wire;
  2. Stripping and wire drawing of the treated steel wire;
  3. Straightening and polishing the treated steel wire.
  4. Heating the treated steel wire to 300-400 degrees.
  5. Melting copper into water in high temperature furnace.
  6. The steel wire in step D is coated with copper water in step E and then cold crystallized to form the product.

 

Preferably, the  copper plated steel wire  surface treatment in step A is a mechanical grinding treatment without water contamination.

 

The invention provides a production method of copper clad steel. The conductivity of the product obtained by the method is close to that of the pure copper product, the cost is greatly reduced, and the service life is prolonged.

 

Ningbo Zhenhai Beisuda Petrochemical Equipment Co.,Ltd located in Ningbo, Zhejiang, it is a professional enterprice, who focus on production and sales of copper clad earth rod. We welcome merchants from all over the world to cooperate with our factory for mutual benefit and win-win, and jointly create a better future.

8466589296?profile=original8466590276?profile=original8466531267?profile=original

Read more…

COPPER-CLAD STEEL GROUNDING CONDUCTORS

Copper clad ground wire is a new material developed by Ningbo Zhenhai Beisuda Petrochemical Equipment Co.,Ltd. to replace pure copper. Copper-clad copperweld steel copper clad rod has the following advantages:

With high strength

With low price

High corrosion resistance

High electrical conductivity of copper

APPLICATIONS OF CCS GROUNDING GROUND CONDUCTORS

In recent years, the copper coated grounding wire has been widely applied to UHV lines, petrochemicals, nuclear power, high-speed rail, especially key projects. Copper-clad steel: A material in which the surface of a steel core is uniformly coated with copper, including copper-clad steel bars (for vertical grounding only), copper-clad steel flat steel, and copper-clad steel wire (including copper-clad steel round wire and copper-clad steel stranded wire).

8466530068?profile=original8466529498?profile=original8466530085?profile=original8466529886?profile=original

Read more…

Exothermic Welding

Exothermic welding, also called hot melt welding, fire-clay welding, thermite welding and explosion welding, is a high-heat principle that utilizes the redox reaction between metals, the operation of which is simple, easy to learn, safe and efficient, and it has significant results in the production of high quality permanent welded joints between homogeneous metals and metals of different materials and is now well known to the public, becoming more popular in more and more architectural designs, and widely required to replace the connection method using conventional metal fixtures.

 

Exothermic welding products require high-quality graphite to form a cavity mold with a certain shape, such as line style (butt), T-joint (three-way), cross-type joint (four-way) and so on. The mold can be used multiple times, effectively saving costs.

Exothermic Welding Advantanges:

  1. Good electrical conductivity: the current-carrying capacity of the welded joint surface is almost the same as that of the metal conductor, and the electrical conductivity is strong.

Experiments have shown that the the change rate of DC resistance before and after welding is close to zero, which is incomparable with any traditional connection mode.

  1. Long and durable life: due to the high temperature fusion between the metal conductors during exothermic welding, an integrated permanent joint is formed, which is very strong and difficult to break and damage.
  2. Strong corrosion resistance: the material of the welded point is mainly copper, and the corrosion resistance is almost the same as that of copper.
  3. The operation is convenient and simple with no need for professionals but can be performed only after pepole are simply trained by professionals.
  4. The requirement for operating environment is low, and no external power source or heat source is required for welding.

 

Operation flow of hot-melt welding

  1. First, the mold and the copper clad steel groundingshould be cleaned, and then the welded conductor should be fixed at the center of the mold cavity.
  2. Close the mold and steadily place a metal protective gasket on the bottom of the mold furnace.
  3. Pour in the exothermic welding flux, and evenly spread the starting powder on the surface of the flux and place it in an environmentally friendly starting powder.
  4. Cover the mold, expose a part of the pyrophoric wrap at the mold opening, and then ignite the starting powder with an igniter.
  5. After the hot-melt flux is ignited, a high temperature reaction occurs in the mold.
  6. After the reaction is completed and cooled, the mold is opened and the welded conductor has been permanently connected.

Welding For Grounding Precautions Flammable and explosive articles shall not be placed within 2 meters of the site during construction operation. Unrelated personnel shall not stay and operators must wear heat insulation gloves and related protective equipment.

 

We can provide you various exothermic welding supplies, RFQ today!

8466529281?profile=original8466529670?profile=original8466529298?profile=original8466529484?profile=original8466529683?profile=original

Read more…

BEST Grounding Module

Performance and characteristics of BEST grounding module:

The low-resistance grounding module is a non-metallic material-based grounding body composed of non-metallic minerals with good conductivity and chemical stability, metal ground rods, electrolytes and humectants.

 

Ground Module performance and characteristics

  1. The contact resistance is greatly reduced.

The main material of the grounding module is similar to the physical structure of the soil, and can be integrated with the soil, so that the effective contact area between the grounding body and the soil is increased by many times compared with that between the traditional metal grounding body and soil, which has increased the flow area of the grounding body itself and greatly reduced contact resistance of the grounding body to the soil.

 

  1. The copper clad steel groundingresistance is stable

The grounding module has strong moisture absorption and moisturizing ability, ensuring that the grounding module can effectively play the conductive function. At the same time, the conductive characteristics of the grounding body are not affected by the weather changes such as dry humidity, high and low humidity. Therefore, it can provide a stable low grounding resistance.

  1. Reduce ground potential counterattack

The non-metallic material in the grounding module forms a low-resistance region with a gentle change between the metal and the soil with a large difference in electrical resistivity. When encountering a large current surge, the potential gradient of the grounding body and the grounding wire can be lowered to lower the step voltage and the contact voltage so as to reduce the probability of counterattack of the ground potential.

 

  1. Long service life

The main material of the grounding module is similar to the physical structure of the soil, and can be integrated with the soil, so that the effective contact area between the grounding body and the soil is increased by many times compared with that between the traditional metal grounding body and soil, which has increased the flow area of the grounding body itself and greatly reduced contact resistance of the grounding body to the soil.

 

  1. Simple construction and installation

Compared with the traditional metal grounding device, the construction work is greatly reduced.

 

Ground module use range:

  1. Working grounding, safe grounding and lightning protection for power plants, substations, switching stations, high-voltage transmission lines, electrified railways, telecommunications, mobile communication base stations, microwave relay stations, ground satellite receiving stations and radar stations;
  2. Working grounding and protective grounding for valuable precision instruments, computer room equipment, postal and telecommunications program control equipment, radio and television equipment, and electronic medical equipment;
  3. Lightning protection of various high-rise buildings, tall structures, scenic ancient buildings and tall memorial towers;
  4. Lightning protection of oil pipelines, oil and gas tanks, and inflammable and explosive material warehouses.

 

Ground Module usage method:

  1. The low-resistance grounding module can be vertically embedded or horizontally embedded, and the  embedded depth should not be less than 0.6 m, generally 0.8- 1.0 m.
  2. When several modules are embedded in parallel, the module spacing should not be less than 4.0 meters. If the conditions are not allowed, it can be appropriately reduced. At the same time, the value of the module utilization coefficient should be reduced when the amount of module is calculated.
  3. When the module pole cores are connected in parallel or connected to the ground wire, they must be welded, with the welding length no less than 100mm.
  4. The welding slag should be removed at the weld, coated with anti-corrosive conductive paint or wrapped with HD-JZ high-efficiency swelling resistance-reducing agent.
  5. During backfilling, it should be sprinkled with water in an appropriate amount, tamped in layers and watered again after backfilling. Meanwhile, the grounding resistance should be measured after the module is fully hygroscopically absorbed (72 hours).

 

Ground Module Specifications:

Product Name

Model No.

Dimension

Weight(KG)

Note

Cyliner Graphite mould

BSD-GMC

D160*800

30

 

D260*1000

50

Plum blossom Graphite mould

BSD-GM-PB

D160*800

30

 

D260*1000

50

Square graphite mould

BSD-GM-FS

500*400*60

20

 

Precautions;

  1. The storage module should maintain a certain humidity to avoid high temperature, dryness and explosion;
  2. External force should be avoided to damage modules during transportation and installation;
  3. In cold areas, the module should be embedded below the frozen layer.

 

Usage calculation

According to the soil resistivity of the grounding network soil layer, the amount of HD-GO grounding module is calculated by the following formula; horizontal embedding, single module grounding resistance: total grounding resistance after parallel connection.

In the formula

ρ- soil resistivity (Ω.m)

a and b- length and width of the grounding module (m)

Rj- single module grounding resistance (Ω)

Rnj- total grounding resistance (Ω)

n- number of grounding modules

η- module adjustment factor, generally 0.6 -0.9

8466537084?profile=original8466536657?profile=original8466536674?profile=original8466536875?profile=original

Read more…

What is the copper bonded earth rod?

What is the copper bonded earth rod?

Product Name: Copper coated copperweld steel ground rod

Production process: electroplating / continuous electroforming

Raw materials: Cold draw high quality mild steel

Product type: one pointed, one flat, two threads (requires with a striker, connector, drill)

Thread production process: mainly consists of two processes: turning before electroplating and rolling after electroplating

Tensile strength: 450-600MPA

Copper layer thickness: more than 0.254mm

Super copper thickness: 0.33-1mm

 

Why choose our Copper-bonded steel ground rod?

  1. Factory history 30 years
  2. Export history 10years
  3. Quality control
  4. Technical skill(copper thickness 0.5mm/0.8mm/1mm)
  5. OEM service
  6. Free sample

Copper-bonded copperweld steel ground rod advantags:

  1. Higher tensile strength than pure copper ground rod, can be as high as 600MPA and above
  2. Superior corrosion resistance: underground service life of up to 30-50 years
  3. Compared with pure copper ground rod, it has excellent electrical conductivity of copper and saves cost.
  4. Compared with traditional galvanized ground rods, the conductivity is higher and the corrosion resistance is stronger.
  5. The connection to the grounding grid can be made by exothermic welding, integrated and molded, and the grounding resistance is small, making it a permanent maintenance-free grounding device.

Production reference standard: US UL467, national grid production enterprise standard QDW466-2010, etc.

Copper-bonded copper clad rod application range:

Lightning protection grounding projects in petrochemical plants, oil storage, power plants, substations, communication base stations, airports, network equipment rooms, etc.

Remarks: Copper-bonded copperweld steel copperweld ground rod steel material and copper plating thickness can be customized according to requirements, the company provides OEM service.

 

Copper-bonded copperweld steel ground rod specification

  1. Copper layer 0.254mm

Model No.

Diameter and Length

Unit Weight

Pack

mm

Kg

BSD-GR1312

13 x 1220  (1/2in x 4ft)

1.27

10

BSD-GR1315

13 x 1500  (1/2in x 5ft)

1.56

10

BSD-GR1318

13 x 1800  (1/2in x 6ft)

1.87

10

BSD-GR1324

13 x 2400  (1/2in x 8ft)

2.50

10

BSD-GR1330

13 x 3000  (1/2in x 10ft)

3.13

10

BSD-GR1412

14.2 x 1220  (5/8in x 4ft)

1.53

10

BSD-GR1415

14.2 x 1500  (5/8in x 5ft)

1.91

10

BSD-GR1418

14.2 x 1800  (5/8in x 6ft)

2.31

10

BSD-GR1424

14.2 x 2400  (5/8in x 8ft)

3.05

5

BSD-GR1430

14.2 x 3000  (5/8in x 10ft)

3.83

5

BSD-GR1718

17.2 x 1800  (3/4in x 6ft)

3.37

5

BSD-GR1724

17.2 x 2400  (3/4in x 8ft )

4.55

5

BSD-GR1730

17.2 x 3000  (3/4in x 10ft )

5.58

3

BSD-GR2530

25 x 3000  (1’ x 10ft )

9.8

3

  1. Copper layer 0.33-0.5mm

Model No.

Diameter and Length

Unit Weight

Pack

mm

Kg

BSD-GR1312

13 x 1220  (1/2in x 4ft)

1.275

10

BSD-GR1315

13 x 1500  (1/2in x 5ft)

1.565

10

BSD-GR1318

13 x 1800  (1/2in x 6ft)

1.88

10

BSD-GR1324

13 x 2400  (1/2in x 8ft)

2.51

10

BSD-GR1330

13 x 3000  (1/2in x 10ft)

3.14

10

BSD-GR1412

14.2 x 1220  (5/8in x 4ft)

1.54

10

BSD-GR1415

14.2 x 1500  (5/8in x 5ft)

1.92

10

BSD-GR1418

14.2 x 1800  (5/8in x 6ft)

2.33

10

BSD-GR1424

14.2 x 2400  (5/8in x 8ft)

3.07

5

BSD-GR1430

14.2 x 3000  (5/8in x 10ft)

3.87

5

BSD-GR1718

17.2 x 1800  (3/4in x 6ft)

3.39

5

BSD-GR1724

17.2 x 2400  (3/4in x 8ft )

4.57

5

BSD-GR1730

17.2 x 3000  (3/4in x 10ft )

5.60

3

BSD-GR2530

25 x 3000  (1’ x 10ft )

9.85

3

Remark: If you want to earth rod suppliers,please contact us, we off OEM service.8466529886?profile=original8466531655?profile=original8466531480?profile=original8466531498?profile=original

Read more…

Chemical Ground Electrode System

Performance characteristics and working principle of Chemical Ground Electrode:

  1. Chemical ground electrode
  2. Existing soil
  3. Special filler
  4. Ions diffuse around
  5. Expand the conductive range of the soil

 

installation earth electrode is a new type of grounding system suitable for all kinds of places with high grounding requirements and difficult grounding engineering.

 

The chemial grounding electrode system  consists of advanced alloy compounds, with a copper tube on the outside to ensure maximum conductivity and long service life. The filling material inside the conductor contains special ionic compounds, which can absorb moisture in the air adequately. Active ions can be effectively released into the soil through the deliquescence, and interact with the moisture in the soil and air to further promote the external slow release and drag reduction of conductors, and to maintain the long-term stability of the resistance value. Compounds in conductors are gradually combined in colloidal transparency over time.

By utilizing the conductivity of the colloidal compound, the entire system can be ion-exchanged for a long time, thus forming an ideal electrolytic ion grounding system. After the slow-release filler in the conductor is embedded, the grounding resistance will gradually decrease, reaching a stable value within six months to one year, and the embedded slow-release process can last for several years. The main connecting parts of the ion grounding electrode are hot-melt welded, which has overcome other connection methods and easy connection loosening.

 

The connecting wire is a copper clad steel copperweld stranded wire with a section of 95 mm2 and a length of 3 m and is crimped to the grounding terminal/copper lug to facilitate connection with the copper clad steel grounding.

 

Chemical Ground Rod Specification and models

Products

Models No.

Diameter

mm

Length

mm

Weight

Kg

Impules current

PH Value

(ΔR)

100Ω·M

Chemical ground Electrode

BSD-CGES55

55

1500

10

≤1%

7+/-5%

0.6

3000

20

≤1%

7+/-5%

0.4

The grounding electrode of BEISUDA COMPANY electrolytic ion fully meets the requirements of grounding protection equipment such as UL, NEC, ANS, lEC, BC and other international standards.

 

Chemical Ground Electrode application range

Lightning protection and grounding works for petrochemicals, oil storage, power plants, substations, communication base stations, airports and network computer rooms, etc.8466530068?profile=original8466531084?profile=original8466530671?profile=original

Read more…

The copper-clad strand wire is shaped like a cable ccs, which is made of a plurality of copper-clad single wires. Because of its multi-stranded properties, the electrical conductivity and tensile strength are relatively good, and the product can be customized to enhance the elongation rate by multiple heat treatment in the production process, which has increased the strength and toughness of the steel compared with the pure copper strand. Moreover, the good electrical conductivity and corrosion resistance of the copper material are maintained due to the principle of the skin effect. Therefore, it is very popular in many fields of lightning protection and grounding, especially in power plants, substations, high-speed rail, subways, electrified railways, large-scale chemical plants, mechanical plants, communication base stations, transportation, computer rooms, highways and military bases.

 

Copper Clad Steel Stranded Wire Characteristics

1.High conductivity (up to 70% and above)

The copper-clad strand wire produced by our company generally has a conductivity of 30%-70%, and more than 70% can be customized according to customer requirements.

2.High tensile strength

The multi-stranded copper-clad strand wire has high tensile strength and can be made into copper-clad steel strand wire with high electrical conductivity and high tensile strength after being enhanced by special treatment process to be suitable for special use occasions.

CCS-Stranded Copper Clad Rod

Cable Welding Capsule New

3.Long life

The copper plating of single-stranded copper-clad round steel (copperweld steel) of multi-stranded copper-clad strand is thick, the excellent production process makes copper layer tightly combined and bent 180-360 degrees without cracking and its life is long and can be more than 30 years.

4.Low cost

The characteristics of high conductivity and corrosion resistance have greatly reduced the number of grounding conductors used in grounding projects, which can significantly save costs and achieve outstanding economic benefits.

5.Convenient construction and transportation

The single length of the copper-clad copperweld strand can be up to 100 meters, because the 100-meter package or the hundred-meter cable can be transported more easily. The welding between the grounding grids during the construction is recommended to use the exothermic welding series products produced by our company. There are different shapes of molds for exothermic welding, so that different permanent joints can be randomly welded. The construction operation is simple and easy to learn, and the various conductors of the grounding grid are welded together to become a true maintenance-free device.

Specification and modles:

Model No.

Size

Strands*sigle path

Diameter

Conductivity

mm2

mm

%

BSD-10C

10

7*1.4

4.2

18%---70%

BSD-16C

16

7*1.7

5.1

18%---70%

BSD-25C

25

7*2.14

6.42

18%---70%

BSD-35C

35

7*2.52

7356

 

BSD-50C

50

7*3.00

9

18%---70%

BSD-70C

70

19*1.44

10.7

18%---70%

BSD-95C

95

19*2.52

12.6

18%---70%

BSD-120C

120

19*2.80

14

18%---70%

BSD-150C

150

19*3.15

15.75

18%---70%

BSD-185C

185

37*2.52

17.64

18%---70%

BSD-240C

240

37*2.85

19.95

18%---70%

BSD-300C

300

37*3.15

21.7

18%---70%

Note: tinned copper-clad strands and PVC insulated copper-clad strands can be customized according to customer requirements.8466529498?profile=original8466535679?profile=original8466535696?profile=original8466535096?profile=original8466536063?profile=original

Read more…

0.8 Series CCS Round Wire

Origin of new material development

0.8mm series copper-clad round wire is a new type of material developed by our Company to replace pure copper. Because it has the advantages of high strength, low price, high corrosion resistance and high conductivity of copper, and meanwhile its comprehensive performance is high and its cost is more economical than pure copper grounding device, it has been widely used in UHV lines, petrochemical industry, nuclear power and high-speed railway, especially in key projects in recent years.

coated ground wire:

The material in which the surface of a steel core is uniformly coated with copper includes copper-clad steel bars (for vertical grounding electrode only), copper-clad steel tape, and copper-clad steel wires (including round wires and stranded wires). According to the production process, it can be divided into continuous casting copper-clad steel and electroplating copper-clad steel.

Development of copper clad steel grounding device

With the increasing voltage level of power lines and the increasing capacity of the system, higher requirements are put forward for the safety and reliability of grounding devices.

 

The traditional method in foreign countries is to use pure copper as the grounding material, but pure copper is expensive and it is a strategic resource, which is not suitable for being massively used as grounding devices in China. From 1910 to 1955, National Bureau of Standards (NBS) conducted corrosion resistance studies of grounding bodies. 36,500 samples collected at 128 test sites throughout the United States represented 333 metal materials consisting of iron, non-ferrous metals and protective coatings, respectively. The test results show that only steel bars and stainless steel bars with copper plating thickness over 0.5mm can be accepted.

 

In addition, continue the statistical data of 8 to 30 years and take the test results of 43 copper samples in different soils, 41 of which were calculated, to get the 0.17mm average pitting depth of 30 years. Therefore, some international standards have determined the thickness of copper coating of copper-clad steel material to be at least 0.25 mm. Considering the hard friction during construction, it is suggested that the thickness of copper coating be defined as 0.5-0.8 mm.

 

In China, copper clad(copperweld) steel materials are widely used in substation grounding grids in areas with high soil resistivity. Because of the characteristics of UHV project, such as high voltage level, large capacity and short power cut window period, combined with the corrosion intensity of groundwater in the area, copper-clad steel grounding devices have been applied in UHV lines and many UHV lines in China use copper-clad steel materials as grounding bodies.

Comparison between copper-clad steel grounding and traditional hot-dip galvanized steel grounding device

  1. Corrosion rate comparision

Annual corrosion rate of grounding materials in some place of Beijing and Tianjin

Material

Beijing Liangxiang

Tianjing Dongli

Stainless stell

0.002

0.003

Pure coper

0.001

0.001

Copper-cald stell

0.001

0.001

Galvanized steel

0.176

0.2

The test results show that galvanized steel has the most serious corrosion and its corrosion rate is more than 50 times higher than that of pure copper; the corrosion degree of stainless steel is much lower than that of pure copper and copper-clad steel, showing good corrosion resistance; as a copper-steel composite material, the self-corrosion potential of copper-clad steel in soil is basically the same as that of pure copper, and its corrosion rate is the same as that of pure copper; the corrosion rate of the electroplated copper-clad steel with thinner coating is higher than that of the continuous casting copper-clad steel with thicker coating.

 

  1. Analysis and comparison of physical performance in short circuit

If the conductivity of copper were 100% and the conductivity of standard 1020 steel were only 10.8%, the conductivity of copper would be about 10 times that of steel. However, the conductivity of the 30% conductivity copper-clad round wire would be 30%, and the conductivity of the 40% conductivity copper-clad round wire would be 40%, which would be far better than the steel grounding body. Especially under skin effect, the conductivity of copper-plated strands at high frequencies would be much better than that of steel, that is, the conductivity of copper grounding body would be better than that of steel grounding body. The melting point of copper is 1083℃ and the maximum allowable temperature during short circuit is 450℃ ; the melting point of steel is 1510℃ and the maximum allowable temperature during short circuit is 400℃. Therefore, when the grounding body has the same cross section, the copper-clad steel grounding material has better thermal stability.

 

  1. Economic comparison

According to Appendix D of Technical Conditions for Copper-clad Steel for Grounding in Electrical Engineering, the corrosion rates of copper clad steel in different soils are calculated according to the reference values in table. Corrosion rate of pure copper under different soil corrosion grades (mm/a)

Soil corrosion grade

La extremely weak corrosion

Lb Weak corrosion

II Strong corrosion

III Extremely strong corrosion

Corrosion rate

0.0004-0.001

0.001-0.004

0.004-0.007

0.007-0.021

 

The 0.8mm copper plating thickness is enough to meet the requirement of 60 years of service under the grade of III extremely strong corrosion.

The corrosion rate of galvanized steel is nearly 50 times that of copper-clad steel under the same soil conditions, and the grounding body should be overhauled after being used for 3-5 years.

 

The State Grid has accounted the UHV tower according to the drawings: after the investigation of the market price of material during the construction, the market price of the copper-clad-steel grounding body is calculated at RMB 20 /m, the market price of φ12 galvanized-steel round steel grounding body is calculated at RMB 6 /m and the grounding body laying is calculated according to the grounding construction drawing. During the 30-year whole life cycle, galvanized steel is overhauled every 5 years, of which the cost of material is RMB 20 /m for copper-clad steel and RMB 36/m for galvanized steel, that is, only material cost can be reduced by 80%. Galvanized steel can be overhauled and replaced six times. If the construction cost is RMB 70 /m3 for earthwork and stone works and each base tower is calculated by 23 m3 for excavation, RMB 9660 per base tower will be saved.

 

Copper-clad steel construction

The horizontal laying of the copper-clad steel grounding device is the same as that of the ordinary galvanized round steel, where only the connection method is changed to hot-melt welding, which has reduced the contact resistance between the joints and is more conducive to the release of lightning current.

Exothermic welding, also known as "aluminum heat welding", is a simple, high-efficiency, high-quality metal joining process that has been mass-produced and used in China in recent years. Exothermic welding uses chemical reaction heat of metal compounds as heat source and through superheated (reduced) molten metal or indirect heating, a certain shape and size of the melted joint is formed in the cavity of the special graphite mould, which meets the engineering requirements, and finally through cooling and condensation, the welding process is realized. At present, exothermic welding has generally replaced the mechanical connection between metals in the past.

 

Advantages of copper-clad steel

1.It has strong corrosion resistance and will not be disjointed, warped or cracked. The corrosion in the grounding body of the grounding grid is reduced, which has improved the overall operational safety of the equipment;

  1. It has good electrical conductivity and stable electrical performance;
  2. The copper layer and the steel bar achieve molecular bonding, and the grounding bar will not break down when it penetrates into the soil.
  3. The copper-clad-steel grounding material used has high efficiency of reducing the resistance, and the length of the horizontal grounding body is reduced by 1/3 for the design of the high-resistance section, greatly reducing the excavation amount of the earthwork;
  4. The design and use of exothermic welding technology is very suitable for the needs of field construction, greatly improving work efficiency and effectively shortening the construction period.

 

Performance parameters of copper-clad steel wire

Copper layer thickness:0.8mm; tensile strength: greater than 500MPa; copper-clad steel bent 180° without peeling off copper layer.

Specification of 0.8mm series copper-clad round steel: Soft copper-clad round bars are generally packaged in hanks or rolls, 100 meters per roll, easy to transport, suitable for laying of large grounding grids and horizontal grounding lines.

Usage:key projects, large grounding grids and horizontal grounding wires in industries with higher lightning protection requirements, etc.

Model No.

Dimeter(mm)

Copper Layer(mm)

BSD-GW-R10S

10

0.8/0.5/0.25

BSD-GW-R12S

12

0.8/0.5/0.25

BSD-GW-R14S

14

0.8/0.5/0.25

Note:

  1. If the thickness of copper layer is required to be 1 mm, please contact us directly.
  2. We undertake custom-made zinc-clad steel ground rod and round steel.

Production method of copper clad steel technical field The invention specifically relates to a production method of copper clad steel.

 

Background technologycopper clad steel

The conductivity of existing copper clad steel products is not good, far inferior to that of pure copper products. The reason is that the overall product performance is insufficient when copper is coated on steel materials in the process.

 

Summary of the invention

In view of the above technical problems, the invention provides a production method of copper clad steel.

A copper clad steel production method comprises the following steps:

  1. Surface treatment of steel wire;
  2. Stripping and wire drawing of the treated steel wire;
  3. Straightening and polishing the treated steel wire.
  4. Heating the treated steel wire to 300-400 degrees.
  5. Melting copper into water in high temperature furnace.
  6. The steel wire in step D is coated with copper water in step E and then cold crystallized to form the product.

 

Preferably, the steel wire surface treatment in step A is a mechanical grinding treatment without water contamination.

 

The invention provides a production method of copper clad steel. The conductivity of the product obtained by the method is close to that of the pure copper product, the cost is greatly reduced, and the service life is prolonged.

We are one of the leading copperweld copper clad steel wire suppliers, RFQ today!8466530900?profile=original8466531067?profile=original

8466531267?profile=original

Read more…